SYCOM Brand Whole House Panel Arrester

120/240 Commercial and Residential Surge Protector is designed for whole house protection on any hardwire application. Connects to a 220 Breaker in your breaker panel.

$76.00

Product Description

120/240 Commercial and Residential Surge Protector is designed for whole house protection on any hardwire application. Connects to a 220 Breaker in your breaker panel.

AC-Disconnect-001-MED

Order one for your A/C Unit to help extend the life of your A/C Unit whether it gets struck by lightning or not. Just the sudden surge of the A/C turning on is dampened by this unit making it easier on your A/C unit. Above shows installation picture. Add years to your A/C unit.

Directions for #TC SYCOM Unit ship with product.
Surge protection or surge arresters go by various names for various uses. Breaker panel surge arresters, panel surge arresters, whole house surge arresters, whole house surge suppression, breaker arresters, electrical surge arresters and many more, but there are those that are for simple surges such as when the power is restored after a power outage, or just a typical surge variance in electrical supply and then there is the dangerous type, that which is lightning. Very few surge arresters are actually made to take the millions of volts of a lightning strike gives. You will be hard pressed to find one that is made specifically for lightning strikes for less money and actually has a wonderful warranty like SYCOM. It is quite obvious that if SYCOM offers a $25,000.00 warranty on all electrical equipment that suffers damage from a lightning strike while being protected by their SYCOM unit, their product must be good. Not all appliances are covered but the majority of the expensive ones are.

The TC Offers the following:

  • Lifetime Warranty on the unit itself.
  • $25,000 Warranty on covered items.

UL Listed and made in the USA Unit Specs:

  • Surge Current: 150,000 Amps
  • Clamping Level: Line to ground 150 VRMS—MOV Rating.Line to Line 310 VRMS—MOV Rating
  • Response Time 5 Nanoseconds
  • Hardwired in breaker panel.
  • Internal Thermal Fusing.

Size: Enclosure 2-7/8” x 3” x 1-3/8” – Weight 1 lb.Diagnostic Light to let you know when it is no longer functioning.

Order one for your A/C Unit to help extend the life of your A/C Unit whether it gets struck by lightning or not. Just the sudden surge of the A/C turning on is dampened by this unit making it easier on your A/C unit.

Sample drawing of what the TC unit will look like on your breaker panel.

Installation is easy. Locate a double pole 220 Breaker that is used on a regular basis so if the unit stops functioning you will know right away in order to make your warranty claim. Connect the wires per instructions that come along with the unit. If the breaker ever takes a lightning hit you may have to reset the breaker. If the breaker does not reset, the unit must be disconnected and then replaced. The breaker will then be able to be reset after the unit is removed. These units have been known to take up to 6 or 8 strikes before they stop working, depending upon the severity of the strike. As long as your panel has power, the LED should remain lit. When it no longer stays lit, it is time to replace the unit.